Operating Manual
ventus
12 G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
Figure 1:
Fastening to
the Mast
9 Installation
The sensor bracket is designed to be installed on the top of a mast with a diameter of 50mm
or 2”.
The following tools are required for the installation:
Hexagon socket 4.0
Compass for aligning
ventus
to the North
9.1 Fastening
Loosen nuts
Push the sensor onto the top of the mast from above
Align the sensor to the North
Tighten both nuts evenly and secure with locking varnish
Mast tube
Nuts
Nuts
approx. 150 mm
approx. 170 mm
page 1/3
Ultrasonic Anemometer Lufft V200A-UMB
Description
Extremely precise and maintenance-free measurement of wind velocity and wind direction as well as calculation of
acoustic virtual temperature. The ultrasonic wind sensor is seawater-resistant and designed without mechanical parts
as they have been used with traditional “cups and vanes”. The sensor is heated to remove frost and ice formation from
the sensor.
The digital or analog output delivers instantaneous, average, min or max value with exible measuring rate. We recom-
mend using the Modbus RTU protocol for applications with Ammonit Meteo-40 data loggers.
Wind speed and direction
The wind measurement element uses 4 ultrasound sensors which take cyclical measurements in all directions. The
resulting wind speed and direction are calculated from the measured run-time sound differential.
Virtual temperature
Due to the physical relationship between the velocity of propagation of sound and the air temperature, the approximate
ambient temperature can be determined with the aid of ultrasound sensors.
Air pressure
The air pressure is measured by an integrated air pressure sensor.
Robust design and precise measurement of wind
speed, wind direction, air pressure and calculation
of acoustic virtual temperature
Maintenance-free - no mechanical parts
Ideal for renewable energy applications
Heating for use in cold weather climates
Plastic housing
Dimensional drawing
Ultrasonic Anemometer Lufft V200A-UMB
Specications
Wind Speed
Measuring range 0 ... 90 m/s
Accuracy ± 0.3 m/s or 3 % (0 ... 35 m/s) RMS, ± 5 % (>35 m/s) RMS
Resolution 0.1 m/s
Wind Direction
Measuring range 0 ... 359.9 °
Accuracy < 3 ° RMSE > 1.0 m/s
Resolution 0.1°
Air Pressure
Principle MEMS capacitive
Measuring range 300 ... 1200 hPa
Accuracy ± 1.5 hPa (0...40 °C)
Resolution 0.1 hPa
Virtual Temperature
Measuring range -50 ... 70 °C
Accuracy ± 2.0 K (without heater and without solar irradiation or wind speed > 4 m/s)
Resolution 0.1 °K
Data Output Digital
Interface RS485 Half-/Full-duplex, isolated
Baud rate 1200 ... 57600
Meas. rate instant. value 1 ... 10 s
Meas. Avg (arith., vec.), Min, Max 1...10 min
Status Heating, sensor failure
Data Output Analog
Data output analog Half-duplex mode
Output signal 0 ... 20 mA, 4 ... 20 mA, 0 ... 10 V, 2 ... 10 V,
2 ... 2,000 Hz (instantaneous, avg, min, max)
Load Max. 300 Ω
Resolution 16 bit
General
Bus operation Up to 32 devices
Operating voltage Power supply electronics:
Power supply electronics + heating:
12 ... 24 VDC ±10%
12 ... 24 VDC ±10%
50 mA
900 mA
Electrical connection 8-pole plug
Ambient temperature -40 ... 60 °C (with heating) / -20 ... 60 °C (without heating)
Dimensions and weight Ø approx. 150 mm, height approx. 170 mm / approx. 0.8 kg
Protection type IP66
Manufacturer G. Lufft Mess- und Regeltechnik GmbH
Ammonit Meteo-40 RS485-M (Half-duplex, 2-wire)
Accessory Module set M83575 (set includes module M83570 and isolated repeater
M84100)
page 2/3
Sensor connection diagram to Ammonit Meteo-40 data logger
Ultrasonic Anemometer Lufft V200A-UMB
page 3/3
Sensor connection to Ammonit Meteo-40 data logger
Sensor Plug
Pin No.
Ammonit Cable
Wire Colour (I)
Ammonit Cable
Wire Colour (II)
Meteo-40
RS485 M
Supply
Sensor
TXD/RXD- 2 brown brown RS485 A (-)
TXD/RXD+ 5 white white RS485 B (+)
Control 3 green green
AGND 6 yellow yellow GND
Supply / Heating 8 red, pink black 1,2 H1: 12 ... 24 VDC
Ground 7 blue, grey black 3,4 H2: GND
Connect the shield logger-sided to Ground (GND)
(I) Cable type without heating: LiYCY 4 x 2 x 0.25 mm²
(II) Cable type with heating wires: CP 4 x 0.75 mm² + 2 x 2 x 0.14 mm²