Order-No.: S42100 – Temperature Sensor TP
S52100 – Temperature Humidity Sensor KP
S50050 – Weather- and Radiation Shield
Measurement principle
The temperature humidity sensors are compact sensors in a rod-
design with plug-in connection to measure relative humidity and
temperature (individually or together) with high precision in air an
other non-aggressive gases. The delivery includes the coupling
plug.
The relative humidity is measured by a capacitive sensing element
and the value will be placed at the output as analog output as well.
Temperature Humidity Sensor
Mounting
The sensors are to be mounted at a climate representa-
tive spot. For protection against rain and direct radiation a
weather and radiation shield should be used, which can be
simply  xed to a mast.
Please order the weather and radiation shield separately!
Take care of a good ventilation of the sensing element. any
mouting position is possible. Avoid penetration of water.
Dew-formation does not do any harm to the element, but
faulty measurements will occur until total drying.
Maintenance
The temperature sensor is maintenance-free. Only check
the output after long use with a precise reference ther-
mometer.
It is possible to make functional gauging of the humidity
sensor. To do this, the sensor has to be exposed to a known
reference humidity, e.g., the available “humidity-standard”
calibration set. If you unscrew the protection  lter, keep in
mind never to touch the element with  ngers or any tool.
Dimensional drawing
page 1/4
Diameter: 123 mm
Height: 208 mm
Overall height including bracket: 300 mm
Weight: 1.01 kg
Temperature Humidity Sensor
Specications
Type Temperature Sensor Humidity Sensor
Measurement principle Pt100 1/3 DIN acc. DIN EN 60751 Capacitive
Measurement range -30 ... +70 °C 0 ... 100% RH
Slope (Data Logger Meteo-40) 100 100
Offset (Data Logger Meteo-40) -30 0
Accuracy
Accuracy ± 0.2 K (-27 ... +80 °C) ± 2% RH (5 ... 95% RH @ 10 ... 40 °C)
Additional error ± 0.007 K/K (<10 °C, >40 °C) < 0.1 %/K (<10 °C, >40 °C)
Operating range
Ambient temperature -40 ... +80 °C
Minimum air speed (across sensor)
0.5 m/s
Electrical data
Output signal 0 ... 1 V 0 ... 1 V
Operating supply 6 ... 30 VDC
Power consumption <1 mA
General
Connection 7-pol plug for shielded cable
Dimensions Sensor: 155 x Ø 20 mm
Weather and radiation shield: see dimensional drawing
Weight Sensor: approx. 0.1 kg
Weather and radiation shield: 1.01 kg
Protection Sensor IP 30
Protection Electronic IP 65
Protection Coupling IP 67
Manufacturer Galltec
page 2/4
Temperature Humidity Sensor
Sensor connection to Ammonit Meteo-40 data logger
TP (temperature only!) - Meteo-40
Order-No. S42100
Sensor Plug Pin No. Ammonit Cable Wire Colour
Meteo-40 Analog Voltage
Supply Sensor
Temperature
Output Voltage
3 white A
x
Ground 2 blue Bx
Supply 4 red 9 ... 30 VDC*
Ground 1 black Main Ground
*Supply voltage for usage with Meteo-40 data loggers
Cable type: LiYCY 4 x 0.25 mm²
Connect the shield logger-sided to Ground (GND)
page 3/4
Sensor connection diagram to Ammonit Meteo-40 data logger
Temperature Humidity Sensor
Sensor connection to Ammonit Meteo-40 data logger
KP (temperature + humidity) - Meteo-40
Order-No. S52100
Sensor Plug Pin No. Ammonit Cable Wire Colour Meteo-40 Analog Voltage Supply Sensor
Temperature
Output Voltage
7 white
Ax
Ground 5 blue Bx
Humidity
Output Voltage
3 brown Ax+1
Ground 2 pink Bx+1
Supply 4 red 9 ... 30 VDC*
Ground 1 black Main Ground
*Supply voltage for usage with Meteo-40 data loggers
Cable type: LiYCY 6 x 0.25 mm²
Connect the shield logger-sided to Ground (GND)
page 4/4
Sensor connection diagram to Ammonit Meteo-40 data logger